This website uses cookies. By using this website you agree to our terms. This website uses cookies, learn more
add listing

Single-core electrical cable FS17 450/750V 1x1.5mm² 100m hank - brown

€ 39.20 + € 5.00 DELIVERY

Description

Single-core electrical cable FS17 450/750V 1x1.5mm² 100m hank - brown Cca – s3, d1, a3 - In accordance with the European Construction Products regulation CPR (EU) n.305/1 Reaction to fire REGULATION 305/2011/EU and Standard EN 50575  Cables suitable for power supply in buildings and other civil engineering works with the aim of limiting the production and spread of fire and smoke. Complying with the Construction Products Regulation (CPR) Standard: EN 50575:2014+A1:2016 Class: Cca-s3, d1, a3 Classification (CEI UNEL 35016): EN 13501-6 Heat and smoke emission during flame development: EN 50399 Vertical flame propagation: EN 60332-1-2 Corrosive and halogen gases: EN 60754-2 Reference standards: CEI UNEL 35716 -CEI EN 60332-1-2 -2014/95/UE -2014/35/UE -2011/65/UE  Cable Description: Indoor power cables and wiring, flexible single-core insulated in S17 quality PVC, fire retardant and with reduced emission of corrosive gases and zero halogens. Conductor: In class 5 flexible round wire annealed red copper.  Soul Isolation: Polyvinyl chloride (PVC) quality S17. Marking: Stamping on the insulation every 1 m. Technical features : Resistant to mechanical stress, non-propagating fire and flame, very low emission of halogens, fumes, toxic and corrosive gases. Good behavior at low temperatures, good flexibility, smoothness and excellent peelability. Good abrasion resistance. Rated voltage: Uo/U: 450/750 V Maximum operating temperature: 70° C Minimum operating temperature: -10° C Maximum short circuit temperature: 160° C Installation conditions: Minimum installation temperature: 5°C Recommended minimum bending radius: 4 times the diameter of the cable Maximum recommended tensile stress: 50 N/mm² of section Packaging: Skeins 100 meters Applications Single-core cables suitable for installation within exposed or recessed pipes, even in places with fire danger, in similar closed systems and in any case only inside buildings. Also used for fixed installation of interruption and control equipment and inside lighting fixtures. Not suitable for outdoor installation. Section  Nominal n° x mmq Diameter  Conductor indicative mm Average insulation thickness mm Maximum external diameter mm Approximate weight Kg./Km. Electrical resistance at 20° C.  Maximum Ω/Km 1X1 1.3 0.7 3.2 14 19.5 1 x 1.5 1.5 0.7 3.5 19 13.3 1 x 2.5 1.9 0.8 4.2 30 7.98 1X4 2.5 0.8 4.8 45 4.95 1X6 3 0.8 6.3 63 3.3 1X10 3.9 1 7.6 100 1.91 1X16 5 1 8.8 159 1.21 1 X 25 6.2 1,2 11 255 0.78 1X35 7.4 1,2 12.5 345 0.554 1 X 50 8.9 1.4 14.5 490 0.386 1 X 70 10.5 1.4 17 680 0.272 1X95 12.2 1.6 19 895 0.206 1X120 13.8 1.6 21 1200 0.161 1 X 150 15.4 1.8 23.5 1400 0.129 1X185 16.9 2 26 1800 0.106 1X240 19.5 2,2 29.5 2400 0.0801

Item Details

9810582
220
Consumer Electronics
27/08/2024
New

Featured Listings

  FEEDBACK